Low Voltage Aerial Bunched Cables

Low Voltage Aerial Bunched Cables

Low Voltage Aerial Bunched Cables

The LV AB cable is a very novel concept in overhead power distribution, as compared with conventional bare conductor in overhead distribution system, AB cables provides higher safety, reliability, lower power losses and ultimate economy by reducing installation, maintenance and operative cost. This superior system is ideal for rural distribution and especially attractive for installation in difficult terrains such as highly areas, forest areas, coastal areas etc. These cables are designed, manufactured & tested conforming to IS: 14255 & other international specifications. AB cables is also considered as choice for power distribution in congested urban areas in developing urban complex AB cables is a better choice because of its flexibility for re-routing as demanded by changes in urban development plan.

  • LV ABCs have stranded aluminum conductors that are insulated with cross-linked polyethylene (XLPE) or polyvinyl chloride (PVC) material. The number and size of the conductors depend on the application and power requirements..
  • The insulation used in LV ABCs provides excellent electrical insulation, and it is designed to withstand harsh environmental conditions such as UV radiation, high temperature, and moisture.
  • LV ABCs are designed to withstand harsh weather conditions and provide reliable performance in extreme temperatures and harsh environments.
  • LV ABCs are easy to install, and they require minimal maintenance. They are lightweight and flexible, which makes them easy to handle during installation.

High insulation resistance to earth in all seasons.

Better adaptability to laid besides with existing overhead bare conductor system without any interference.

Longer spans and longer distance lines are possible with better system stability.

It can be laid in dense vegetation and forest areas.

Maintenance is very convenient.

  • Less fault rate on account of good protection against line and ground faults by high winding falling trees or birds specially in hilly areas and forests
  • Multiplexer circuits of power and telephone cables could be in the same set of poles.
  • High capacitance and low inductance leading to low impedance of lines.
  • AB cables are much safer than bare conductors.

Cross-Linked Polyethylene (XLPE): XLPE insulation is a popular choice for LV ABC due to its excellent electrical and mechanical properties. It provides good resistance to moisture, heat, and UV radiation, making it suitable for use in harsh environments.

Polyvinyl Chloride (PVC): PVC insulation is another common type of insulation used in LV ABC. It is known for its durability and resistance to moisture, UV radiation, and temperature. PVC insulation is also cost-effective compared to other types of insulation.

Ethylene Propylene Rubber (EPR): EPR insulation is a highly durable and flexible insulation material used in LV ABC for applications that require high flexibility and mechanical resistance.

Thermoplastic Elastomer (TPE): TPE insulation is a newer type of insulation used in LV ABC that offers good electrical and mechanical properties. It is highly resistant to moisture, temperature, and UV radiation.

“Explore Our Product Carousel”

Low Voltage Aerial Bunched Cables

The LV AB cable is a very novel concept in overhead power distribution, as compared with conventional bare conductor in overhead distribution system, AB cables provides higher safety, reliability, lower power losses and ultimate economy by reducing installation, maintenance and operative cost. This superior system is ideal for rural distribution and especially attractive for installation in difficult terrains such as highly areas, forest areas, coastal areas etc. These cables are designed, manufactured & tested conforming to IS: 14255 & other international specifications. AB cables is also considered as choice for power distribution in congested urban areas in developing urban complex AB cables is a better choice because of its flexibility for re-routing as demanded by changes in urban development plan.

Features

  • LV ABCs have stranded aluminum conductors that are insulated with cross-linked polyethylene (XLPE) or polyvinyl chloride (PVC) material. The number and size of the conductors depend on the application and power requirements..
  • The insulation used in LV ABCs provides excellent electrical insulation, and it is designed to withstand harsh environmental conditions such as UV radiation, high temperature, and moisture.
  • LV ABCs are designed to withstand harsh weather conditions and provide reliable performance in extreme temperatures and harsh environments.
  • LV ABCs are easy to install, and they require minimal maintenance. They are lightweight and flexible, which makes them easy to handle during installation.

Applications

High insulation resistance to earth in all seasons.

Better adaptability to laid besides with existing overhead bare conductor system without any interference.

Longer spans and longer distance lines are possible with better system stability.

It can be laid in dense vegetation and forest areas.

Maintenance is very convenient.

Advantages

  • Less fault rate on account of good protection against line and ground faults by high winding falling trees or birds specially in hilly areas and forests
  • Multiplexer circuits of power and telephone cables could be in the same set of poles.
  • High capacitance and low inductance leading to low impedance of lines.
  • AB cables are much safer than bare conductors.

Insulated

Cross-Linked Polyethylene (XLPE): XLPE insulation is a popular choice for LV ABC due to its excellent electrical and mechanical properties. It provides good resistance to moisture, heat, and UV radiation, making it suitable for use in harsh environments.

Polyvinyl Chloride (PVC): PVC insulation is another common type of insulation used in LV ABC. It is known for its durability and resistance to moisture, UV radiation, and temperature. PVC insulation is also cost-effective compared to other types of insulation.

Ethylene Propylene Rubber (EPR): EPR insulation is a highly durable and flexible insulation material used in LV ABC for applications that require high flexibility and mechanical resistance.

Thermoplastic Elastomer (TPE): TPE insulation is a newer type of insulation used in LV ABC that offers good electrical and mechanical properties. It is highly resistant to moisture, temperature, and UV radiation.

“Explore Our Product Carousel”

Don’t compromise on safety and quality. Choose our Low Voltage Aerial Bunched Cables for your power transmission needs. Request a quote now.